sales@hobertek.com

Modelo de variador

HSPH15KL

A 15 kW HOBER solar pumping inverter for a monofásico / trifásico AC pump on a 220/240 V supply. Para bombas pequeñas, suministro de agua doméstico y riego ligero, con alimentación monofásica.

  • 15 kW
  • 220/240 V
  • Monofásico / trifásico
  • IP65
  • 220/240V 3-Phase
Unidad de variador solar para bombeo HOBER

15 kW · IP65

What this model is

HSPH15KL is a solar pumping inverter for a 15 kW monofásico / trifásico AC pump: not a pump and not a panel, but the drive that stands between the two. The array’s DC comes in, the drive holds the array at its maximum power point, and what leaves it for the pump is AC at the voltage and the frequency the motor was built for. The frequency follows the array rather than a fixed supply, so the pump turns at the speed the sun can pay for at that moment, and the day’s water is pumped while the sun is up. This model also states an AC input: grid or generator is switched in while solar is low, and switched out again as solar recovers. Nothing is stored in a battery: the energy is stored as water in a tank or a reservoir.

An existing 15 kW AC pump does not have to be replaced to run on solar. It needs the right drive in front of it, and HSPH15KL is that drive: the motor, the pipework and the wiring stay where they are.

For this model the datasheet states an array window of 200V minimum Vmp and 650V maximum Voc, 78A of rated input current over 5 strings, MPPT at up to 99%, an output of 220/240 V at 50~60 Hz, an IP65 enclosure for mounting on a wall outdoors, a water level input for a well or a tank and an optional 4G/Wi-Fi module for remote monitoring.

What that buys is a pumping day with no meter running: the fuel bill or the grid bill that used to arrive with every hour of pumping goes, and the pump that was already paid for keeps working. The protections are built in rather than added — Solar DC input Low/Over Voltage, Solar DC Input Reverse Polarity, AC Output Short-circuit, Over Temperature, Over Flow of Tank, Overload, AC Input/Output Phase Lose, Dry-Run, AC Output Unbalance, Over Load, AC Output Over Current — so a dry well, a low array or a hot afternoon costs a shutdown rather than a motor. The array is not guessed either: the array window is what the string has to sit inside, and the sizing is read from the pump’s duty point rather than from a rule of thumb.

To confirm this model against your pump, send the nameplate details — power, voltage, phase and rated current — and we check them against this model’s own figures before anything is ordered. The code to quote is HSPH15KL.

Where it sits in the range

220/240 V single- or three-phase output · 15 kW pump output · IP65

Para bombas pequeñas, suministro de agua doméstico y riego ligero, con alimentación monofásica.

Other models in this family

The datasheet for this model

Every row is a row of the source datasheet, read from this model’s own column, in the sections and the order the source prints them. A row the source does not state for this model carries an em dash rather than a figure borrowed from the model beside it.

Solar Panel DC Input

Solar Panel DC Input, HSPH15KL
Parámetro HSPH15KL
Max Voc Voltage 650V
Min Vmp Voltage 200V
Recommend Vmp Voltage 300V - 500V
Max MPPT Efficiency 99%
Rated Input Current 78A
Number of Strings 5

Hybrid AC/Diesel Input

Hybrid AC/Diesel Input, HSPH15KL
Parámetro HSPH15KL
Voltage 220/240V 3-Phase
Rated Input Current 61A

AC Output

AC Output, HSPH15KL
Parámetro HSPH15KL
Max Adapted AC Pump Horse Power 20HP
Max Adapted AC Pump Power 15KW
Drive Mode Variable Frequency Drive 3-Phase or 1-Phase
Max Output Voltage 220/240V
Max Output Frequency 50~60 Hz
Rated Output Current 3-Phase 60A, 1-Phase 75A
Max Efficiency 97%
AC Supplement Method for Low Power of Solar Panel Automatic

Other Characteristics

Other Characteristics, HSPH15KL
Parámetro HSPH15KL
Water Level Sensor (well / tank) Yes
4G/WiFi Monitor & Controller Optional
Display LCD display
Waterproof IP65
Noise <50dB
Cooling Method Force Cooling by Fan (IP68)
Protection Solar DC input Low/Over Voltage; Solar DC Input Reverse Polarity; AC Output Short-circuit; Over Temperature; Over Flow of Tank; Overload; AC Input/Output Phase Lose; Dry-Run; AC Output Unbalance; Over Load; AC Output Over Current

Operating Environment

Operating Environment, HSPH15KL
Parámetro HSPH15KL
Operating Environment Temperature -10 to 60°C; above 60°C need to derate load
Max Humidity 95%RH
Using Altitude <3000m; above 3000m need to derate load
Installation Restrictions Direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid, etc.

Package

Package, HSPH15KL
Parámetro HSPH15KL
Size (L×W×H) 700×400×285mm
Weight 23KG

Modelo de variador

Order HSPH15KL

Send the pump nameplate details and we confirm this model, the array it needs and the supply it expects.

Selección rápida de bomba Seleccionar bomba Seleccionar por caudal y altura WhatsApp Hable con HOBER