Modelo de inversor
HSPH2200L
A 2.2 kW HOBER solar pumping inverter for a monofásico / trifásico AC pump on a 220/240 V supply. Para bombas pequenas, abastecimento de água doméstico e irrigação leve, em alimentação monofásica.
0.75–2.2 kW · IP65
What this model is
HSPH2200L is a solar pumping inverter for a 2.2 kW monofásico / trifásico AC pump: not a pump and not a panel, but the drive that stands between the two. The array’s DC comes in, the drive holds the array at its maximum power point, and what leaves it for the pump is AC at the voltage and the frequency the motor was built for. The frequency follows the array rather than a fixed supply, so the pump turns at the speed the sun can pay for at that moment, and the day’s water is pumped while the sun is up. This model also states an AC input: grid or generator is switched in while solar is low, and switched out again as solar recovers. Nothing is stored in a battery: the energy is stored as water in a tank or a reservoir.
An existing 2.2 kW AC pump does not have to be replaced to run on solar. It needs the right drive in front of it, and HSPH2200L is that drive: the motor, the pipework and the wiring stay where they are.
For this model the datasheet states an array window of 200V minimum Vmp and 450V maximum Voc, 11A of rated input current over one string, MPPT at up to 99%, an output of 220/240 V at 50-60 Hz, an IP65 enclosure for mounting on a wall outdoors, a water level input for a well or a tank and an optional 4G/Wi-Fi module for remote monitoring.
What that buys is a pumping day with no meter running: the fuel bill or the grid bill that used to arrive with every hour of pumping goes, and the pump that was already paid for keeps working. The protections are built in rather than added — Solar DC input Low/Over Voltage, Solar DC input Reverse Polarity, Over Flow of Tank, Against Lightning, AC input / Output Phase Lost, Dry-Run (detecting by Sensor or Software), AC Output Short-circuit, AC Output Over Current, Over Temperature, Over Load — so a dry well, a low array or a hot afternoon costs a shutdown rather than a motor. The array is not guessed either: the array window is what the string has to sit inside, and the sizing is read from the pump’s duty point rather than from a rule of thumb.
To confirm this model against your pump, send the nameplate details — power, voltage, phase and rated current — and we check them against this model’s own figures before anything is ordered. The code to quote is HSPH2200L.
Where it sits in the range
Single-phase 220/240 V input · 0.75–2.2 kW pump output · IP65
Para bombas pequenas, abastecimento de água doméstico e irrigação leve, em alimentação monofásica.
The whole inverter range The series this model belongs to
Other models in this family
The datasheet for this model
Every row is a row of the source datasheet, read from this model’s own column, in the sections and the order the source prints them. A row the source does not state for this model carries an em dash rather than a figure borrowed from the model beside it.
Solar Input
| Parâmetro | HSPH2200L |
|---|---|
| Max Voc Voltage | 450V |
| Min Vmp Voltage | 200V |
| Recommend DC Input MPPT Voltage | Pure solar input mode: DC input Min Vmp >300V, DC input Max Voc <450V Hybrid DC/AC input mode: DC input Min Vmp >340V, DC input Max Voc <450V |
| Max MPPT Efficiency | 99% |
| Rated Input Current | 11A |
| Number of Strings | 1 |
| Inside Booster | N |
Hybrid AC Input
| Parâmetro | HSPH2200L |
|---|---|
| Voltage | 220/240V 1-Phase |
| Rated Input Current | 15A |
| Hybrid Mode | Automatic. AC supplement automatic while solar low power and AC disconnect automatic while solar power recovery |
AC Output for Pump (AC Induction Motor)
| Parâmetro | HSPH2200L |
|---|---|
| Max Adapted AC Pump Horse Power | 3 HP |
| Max Adapted AC Pump Power | 2200W |
| Phase | Single Phase (1 phase) / 3 Phase (Compatible) |
| Max Output Voltage | 220/240V |
| Max Output Frequency | 50-60 Hz |
| Rated Output Current | 16A |
Other Characteristics
| Parâmetro | HSPH2200L |
|---|---|
| Max Efficiency | 99% |
| Water Level Sensor (well / tank) | Yes |
| 4G/WiFi Monitor & Controller | Support (Optional) |
| Display | LCD Display (128×64) |
| Waterproof | IP65 |
| Noise | <50dB |
| Cooling Method | Force Cooling by Fan (IP68) |
| Protection | Solar DC input Low/Over Voltage; Solar DC input Reverse Polarity; Over Flow of Tank; Against Lightning; AC input / Output Phase Lost; Dry-Run (detecting by Sensor or Software); AC Output Short-circuit; AC Output Over Current; Over Temperature; Over Load |
Operating Environment
| Parâmetro | HSPH2200L |
|---|---|
| Operating Environment Temperature | -10 to 60°C; above 60°C need to derate load |
| Max Humidity | 95%RH |
| Using Altitude | <3000m; above 3000m need to derate load |
| Installation Restrictions | Direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid, etc. |
Package
| Parâmetro | HSPH2200L |
|---|---|
| Size (L×W×H) | 400×310×200mm |
| Weight | 6KG |
Modelo de inversor
Order HSPH2200L
Send the pump nameplate details and we confirm this model, the array it needs and the supply it expects.