sales@hobertek.com

Modelo de inversor

HSPH55KH

A 55 kW HOBER solar pumping inverter for a trifásico AC pump on a 380/400/440 V supply. Para irrigação de grande porte, bombeamento comercial e transposição de água, em alimentação trifásica.

  • 55 kW
  • 380/400/440 V
  • Trifásico
  • IP21
  • 3 Phase 380/400/440V
Inversor solar de bombeamento HOBER de 45–132 kW

45–132 kW · IP21

What this model is

HSPH55KH is a solar pumping inverter for a 55 kW trifásico AC pump: not a pump and not a panel, but the drive that stands between the two. The array’s DC comes in, the drive holds the array at its maximum power point, and what leaves it for the pump is AC at the voltage and the frequency the motor was built for. The frequency follows the array rather than a fixed supply, so the pump turns at the speed the sun can pay for at that moment, and the day’s water is pumped while the sun is up. This model also states an AC input: grid or generator is switched in while solar is low, and switched out again as solar recovers. Nothing is stored in a battery: the energy is stored as water in a tank or a reservoir.

An existing 55 kW AC pump does not have to be replaced to run on solar. It needs the right drive in front of it, and HSPH55KH is that drive: the motor, the pipework and the wiring stay where they are.

For this model the datasheet states an array window of 400V minimum Vmp and 900V maximum Voc, 147A of rated input current over one string, MPPT at up to 99%, an output of 380/400/440 V at 50-60 Hz (support program range 15-60Hz) and an IP21 enclosure for an indoor installation with the switchgear.

What that buys is a pumping day with no meter running: the fuel bill or the grid bill that used to arrive with every hour of pumping goes, and the pump that was already paid for keeps working. The protections are built in rather than added — Solar DC input Low/Over Voltage, Solar DC input Reverse Polarity, Over Flow of Tank, Against Lighting, AC input / Output Phase Lost, Dry-Run (detecting by Sensor or Software), AC Output Short-circuit, AC Output Over Current, Over Temperature, Over Load — so a dry well, a low array or a hot afternoon costs a shutdown rather than a motor. The array is not guessed either: the array window is what the string has to sit inside, and the sizing is read from the pump’s duty point rather than from a rule of thumb.

To confirm this model against your pump, send the nameplate details — power, voltage, phase and rated current — and we check them against this model’s own figures before anything is ordered. The code to quote is HSPH55KH.

Where it sits in the range

Three-phase 380/400/440 V input · 45–132 kW pump output · IP21

Para irrigação de grande porte, bombeamento comercial e transposição de água, em alimentação trifásica.

Other models in this family

The datasheet for this model

Every row is a row of the source datasheet, read from this model’s own column, in the sections and the order the source prints them. A row the source does not state for this model carries an em dash rather than a figure borrowed from the model beside it.

Solar Input

Solar Input, HSPH55KH
Parâmetro HSPH55KH
Max Voc Voltage 900V
Min Vmp Voltage 400V
Recommend DC Input MPPT Voltage Pure solar input mode: DC input Min Vmp >500V, DC input Max Voc <800V
Hybrid DC/AC input mode: DC input Min Vmp >540V, DC input Max Voc <800V
Max MPPT Efficiency 99%
Rated Input Current 147A
Number of Strings 1
Note Automatic MPPT Function to Identify the Voc and Vmp of Solar Panel, without programming

Hybrid AC/Generator Input

Hybrid AC/Generator Input, HSPH55KH
Parâmetro HSPH55KH
Voltage 3 Phase 380/400/440V
Max Input Current 114A
Hybrid Mode Automatic. AC supplement automatic while PV low power and AC disconnect automatic while solar power recovery

AC Output (For Pump, Rerator, Fan Parameters)

AC Output (For Pump, Rerator, Fan Parameters), HSPH55KH
Parâmetro HSPH55KH
Max Adapted AC Pump Horse Power 75 HP
Max Adapted AC Pump Power 55KW
Drive Mode Variable Frequency Drive 3Phase
Max Output Voltage 380/400/440V
Max Output Frequency 50-60 Hz (support program range 15-60Hz)
Rated Output Current 112A

Other Characteristics

Other Characteristics, HSPH55KH
Parâmetro HSPH55KH
Max Efficiency 99%
Water Level Sensor (Borehole / Tank) Yes
GPRS SMS Monitor & Controller Optional
Support Remote Monitoring & Control System Yes
Display LCD display
Waterproof IP21
Noise <75dB
Cooling Method Force Cooling by Fan
Protection Solar DC input Low/Over Voltage; Solar DC input Reverse Polarity; Over Flow of Tank; Against Lighting; AC input / Output Phase Lost; Dry-Run (detecting by Sensor or Software); AC Output Short-circuit; AC Output Over Current; Over Temperature; Over Load

Operating Environment

Operating Environment, HSPH55KH
Parâmetro HSPH55KH
Operating Environment Temperature -10 to 60°C; above 60°C need to derate load
Max Humidity 95%RH
Using Altitude <3000m; above 3000m need to derate load
Installation Restrictions Direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid, etc.

Package

Package, HSPH55KH
Parâmetro HSPH55KH
Size 850×540×440mm
Weight 72KG

Modelo de inversor

Order HSPH55KH

Send the pump nameplate details and we confirm this model, the array it needs and the supply it expects.

Seleção rápida de bomba Selecionar bomba Selecionar por vazão e altura WhatsApp Fale com a HOBER