sales@hobertek.com

طراز العاكس

HSPH2200HB

A 2.2 kW HOBER solar pumping inverter for a ثلاثي الطور AC pump on a 380/400/440 V supply. لمضخات الآبار العميقة والمضخات السطحية وأعمال الري الشائعة، في غلاف للتركيب على الحائط.

  • 2.2 kW
  • 380/400/440 V
  • ثلاثي الطور
  • IP65
  • 3 Phase 380/400/440V
عاكس الضخ الشمسي HOBER، منظر أمامي

1.5–5.5 kW · IP65

What this model is

HSPH2200HB is a solar pumping inverter for a 2.2 kW ثلاثي الطور AC pump: not a pump and not a panel, but the drive that stands between the two. The array’s DC comes in, the drive holds the array at its maximum power point, and what leaves it for the pump is AC at the voltage and the frequency the motor was built for. The frequency follows the array rather than a fixed supply, so the pump turns at the speed the sun can pay for at that moment, and the day’s water is pumped while the sun is up. This model states no AC input, so the array is its only source and the water pumped in a day is what the array delivers. Nothing is stored in a battery: the energy is stored as water in a tank or a reservoir.

An existing 2.2 kW AC pump does not have to be replaced to run on solar. It needs the right drive in front of it, and HSPH2200HB is that drive: the motor, the pipework and the wiring stay where they are.

For this model the datasheet states an array window of 300V minimum Vmp and 700V maximum Voc, 12.6A of rated input current over one string, MPPT at up to 99%, an output of 380/400/440 V at 50-60 Hz (support program range 15 to 60Hz), an IP65 enclosure for mounting on a wall outdoors, a water level input for a well or a tank, an optional 4G/Wi-Fi module for remote monitoring and a built-in booster, which is what lets a shorter string reach that window.

What that buys is a pumping day with no meter running: the fuel bill or the grid bill that used to arrive with every hour of pumping goes, and the pump that was already paid for keeps working. The protections are built in rather than added — Solar DC input Low/Over Voltage, Solar DC input Reverse Polarity, Over Flow of Tank, Against Lightning, AC input / Output Phase Lost, Dry-Run (detecting by Sensor or Software), AC Output Short-circuit, AC Output Over Current, Over Temperature, Over Load — so a dry well, a low array or a hot afternoon costs a shutdown rather than a motor. The array is not guessed either: the array window is what the string has to sit inside, and the sizing is read from the pump’s duty point rather than from a rule of thumb.

To confirm this model against your pump, send the nameplate details — power, voltage, phase and rated current — and we check them against this model’s own figures before anything is ordered. The code to quote is HSPH2200HB.

Where it sits in the range

Three-phase 380/400/440 V input · 1.5–5.5 kW pump output · IP65

لمضخات الآبار العميقة والمضخات السطحية وأعمال الري الشائعة، في غلاف للتركيب على الحائط.

Other models in this family

The datasheet for this model

Every row is a row of the source datasheet, read from this model’s own column, in the sections and the order the source prints them. A row the source does not state for this model carries an em dash rather than a figure borrowed from the model beside it.

Solar Input

Solar Input, HSPH2200HB
المعامل HSPH2200HB
Max Voc Voltage 700V
Min Vmp Voltage 300V
Recommend DC Input MPPT Voltage Built-in booster
DC Min Vmp >340V
DC Max Voc <700V
Max MPPT Efficiency 99%
Rated Input Current 12.6A
Number of Strings 1
Inside Booster Y (Support)
Note Automatic MPPT Function to Identify the Voc and Vmp of Solar Panel, no need programming

AC Input

AC Input, HSPH2200HB
المعامل HSPH2200HB
Voltage 3 Phase 380/400/440V
Rated Input Current 7A
Hybrid Mode N

AC Output for Pump (AC Induction Motor)

AC Output for Pump (AC Induction Motor), HSPH2200HB
المعامل HSPH2200HB
Max Adapted AC Pump Horse Power 3 HP
Max Adapted AC Pump Power 2200W
Drive Mode Variable Frequency Drive 3Phase
Max Output Voltage 380/400/440V
Max Output Frequency 50-60 Hz (support program range 15 to 60Hz)
Rated Output Current 7A

Other Characteristics

Other Characteristics, HSPH2200HB
المعامل HSPH2200HB
Max Efficiency 99%
Water Level Sensor (well / tank) Yes
4G/WiFi Monitor & Controller Optional
Display LCD display
Waterproof IP65
Noise <50dB
Cooling Method Force Cooling by Fan (IP68)
Protection Solar DC input Low/Over Voltage; Solar DC input Reverse Polarity; Over Flow of Tank; Against Lightning; AC input / Output Phase Lost; Dry-Run (detecting by Sensor or Software); AC Output Short-circuit; AC Output Over Current; Over Temperature; Over Load

Operating Environment

Operating Environment, HSPH2200HB
المعامل HSPH2200HB
Operating Environment Temperature -10 to 60°C; above 60°C need to derate load
Max Humidity 95%RH
Using Altitude <3000m; above 3000m need to derate load
Installation Restrictions Direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid, etc.

Package

Package, HSPH2200HB
المعامل HSPH2200HB
Size (L×W×H) 480×310×200mm
Weight 9KG

طراز العاكس

Order HSPH2200HB

Send the pump nameplate details and we confirm this model, the array it needs and the supply it expects.

اختيار سريع للمضخة اختر المضخة الاختيار حسب معدل التدفق والارتفاع واتساب تحدث مع HOBER