Irrigation
Field and orchard irrigation where the pump runs through the day and the water is stored or used as it is pumped.
Solar pump inverters
For sites where the inverter has to raise the voltage itself, because the array cannot be made long enough to reach the pump voltage directly.
0.75–2.2kW | Low PV Voltage Solution
01 / Quick selection
Every model in this collection carries a built-in booster. A model whose specification states none belongs in the collection for its own pump supply.
No model matches this collection yet. Send the pump nameplate and we will confirm what fits.
02 / Key features
03 / Typical applications
Field and orchard irrigation where the pump runs through the day and the water is stored or used as it is pumped.
A daily water demand served from a well, a borehole or a tank, with storage sized around the pumping window.
Pumping into a pressurised line or a distribution network where the pump is asked for a constant pressure.
Larger duties where the inverter is matched to a pump chosen for the duty, and the supply may be three-phase.
04 / System matching and PV sizing
The inverter is chosen from the pump, not the other way round. Send the pump nameplate and we will match it to the model that drives it.
The array, the inverter, the pump: the whole path is checked before a model is proposed
05 / Technical support
Sizing, matching and after-sales questions are answered by the same team that supplies the inverter.
A nameplate photograph is usually enough to start
06 / Questions
It follows the pump supply: 220 V, 230 V or 240 V pumps belong to the 220 V collection, and three-phase pumps on 380 V, 400 V or 440 V belong to the 380–440 V collection.
Yes. A model that states a built-in booster and a 380–440 V pump supply belongs to both collections, because it is one product with two attributes rather than two products.
Send the nameplate. For a pump outside the ranges we cover, we propose the closest model we can supply and state the difference, never a model that does not fit.
Some HOBER inverters carry the booster inside the unit, and this collection is those models: it covers the 0.75–2.2 kW sizes, and a model belongs to the collection only where its specification states a built-in booster. A booster raises the array voltage the drive works at; it does not add energy, so the array still has to be able to supply the pump’s duty. An external add-on booster is a separate arrangement and nothing here implies one — send the motor data and the array you have, and the combination is checked against the selected model.
Solar pump inverters
Send the pump nameplate and the site details. We will come back with the model, the array it needs and the supply it expects.