sales@hobertek.com
HOBER CHL Series Horizontal Multistage Solar Pump 0.37kW to 37kW

Solar Pump

CHL Solar Pump Series

Horizontal multistage pump series, supplied with a HOBER solar pump inverter for pressure boosting and industrial supply on solar DC with grid AC as the alternative.

Flow range of models shown
0.5–28 m³/h
Head range of models shown
6–60 m
Motor power of models shown
0.37–4.4 kW

Ranges are based on the positive-flow catalogue points of the models shown: the point at zero flow is the shut-off point of the curve, not a duty point. More CHL models are available on inquiry. Read flow and head together on the curve for the model selected.

01 / Product & applications

Where this series is used, and the conditions it works in.

Applications

Application
Industrial Water Supply, Pressure Boosting
Water source
Municipal Water, Water Tank
Installation
Surface
Pump type
Horizontal Multistage Pump
System
AC/DC Solar Pump
Power source
Solar + Grid

02 / Model selection

Selected CHL Models

Selected models of this series, with their stated figures and recorded performance curves.

Selected models are shown. More models are available. Contact HOBER for additional models and selection support.

CHL Solar Pump Series models with flow and head range, curve and inquiry
Model Motor power Flow / head range Curve Inquiry
CHL 8 models
0.37 kW 0.5–3.5 m³/h / 7.5–19 m Enquire about this model
0.75 kW 0.5–3.5 m³/h / 24–53.5 m Enquire about this model
0.75 kW 1–7 m³/h / 19–37.5 m Enquire about this model
1.1 kW 5–11 m³/h / 21–29.5 m Enquire about this model
0.75 kW 7–16 m³/h / 6–11.5 m Enquire about this model
3 kW 7–16 m³/h / 35–60 m Enquire about this model
2.2 kW 8–22 m³/h / 16–24.5 m Enquire about this model
4 kW 10–28 m³/h / 23–39.5 m Enquire about this model
CHLF(T) 4 models
1.1 kW 1–7 m³/h / 28–56 m Enquire about this model
2.2 kW 5–11 m³/h / 36–51 m Enquire about this model
4 kW 8–22 m³/h / 33–51 m Enquire about this model
4.4 kW 10–28 m³/h / 32.5–53 m Enquire about this model

CHL2-20

Hide curve
CHL2-207.510.3813.2516.13190.51.2522.753.5Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0.5 m³/h
19 m
1 m³/h
18 m
1.5 m³/h
16.5 m
2 m³/h
15 m
2.5 m³/h
13 m
3 m³/h
10 m
3.5 m³/h
7.5 m

Key figures for this model

Motor power
0.37 kW
Flow / head range
0.5–3.5 m³/h / 7.5–19 m

CHL2-60

Hide curve
CHL2-602431.438.846.153.50.51.2522.753.5Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0.5 m³/h
53.5 m
1 m³/h
51 m
1.5 m³/h
48 m
2 m³/h
44 m
2.5 m³/h
39 m
3 m³/h
32 m
3.5 m³/h
24 m

Key figures for this model

Motor power
0.75 kW
Flow / head range
0.5–3.5 m³/h / 24–53.5 m

CHL4-40

Hide curve
CHL4-401923.6328.2532.8837.512.545.57Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

1 m³/h
37.5 m
2 m³/h
36 m
3 m³/h
34 m
4 m³/h
31 m
5 m³/h
27 m
6 m³/h
23 m
7 m³/h
19 m

Key figures for this model

Motor power
0.75 kW
Flow / head range
1–7 m³/h / 19–37.5 m

CHL8-30

Hide curve
CHL8-302123.1325.2527.3829.556.589.511Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

5 m³/h
29.5 m
6 m³/h
29 m
7 m³/h
28 m
8 m³/h
27 m
9 m³/h
25 m
10 m³/h
23 m
11 m³/h
21 m

Key figures for this model

Motor power
1.1 kW
Flow / head range
5–11 m³/h / 21–29.5 m

CHL12-10

Hide curve
CHL12-1067.388.7510.1311.579.2511.513.7516Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

7 m³/h
11.5 m
8 m³/h
11.2 m
9 m³/h
11 m
10 m³/h
10.5 m
11 m³/h
10 m
12 m³/h
9.5 m
13 m³/h
9 m
14 m³/h
8 m
15 m³/h
7 m
16 m³/h
6 m

Key figures for this model

Motor power
0.75 kW
Flow / head range
7–16 m³/h / 6–11.5 m

CHL12-50

Hide curve
CHL12-503541.347.553.86079.2511.513.7516Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

7 m³/h
60 m
8 m³/h
58 m
9 m³/h
56.5 m
10 m³/h
55 m
11 m³/h
52.5 m
12 m³/h
50 m
13 m³/h
47 m
14 m³/h
44 m
15 m³/h
40 m
16 m³/h
35 m

Key figures for this model

Motor power
3 kW
Flow / head range
7–16 m³/h / 35–60 m

CHL15-20

Hide curve
CHL15-201618.1320.2522.3824.5811.51518.522Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

8 m³/h
24.5 m
10 m³/h
24 m
12 m³/h
23 m
14 m³/h
22 m
15 m³/h
21 m
16 m³/h
20.5 m
18 m³/h
19 m
20 m³/h
18 m
22 m³/h
16 m

Key figures for this model

Motor power
2.2 kW
Flow / head range
8–22 m³/h / 16–24.5 m

CHL20-30

Hide curve
CHL20-302327.1331.2535.3839.51014.51923.528Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

10 m³/h
39.5 m
12 m³/h
39 m
14 m³/h
38 m
16 m³/h
37.5 m
18 m³/h
35.5 m
20 m³/h
34 m
22 m³/h
31.5 m
24 m³/h
29 m
26 m³/h
26 m
28 m³/h
23 m

Key figures for this model

Motor power
4 kW
Flow / head range
10–28 m³/h / 23–39.5 m

CHLF(T)4-60

Hide curve
CHLF(T)4-60283542495612.545.57Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

1 m³/h
56 m
2 m³/h
54 m
3 m³/h
51 m
4 m³/h
47 m
5 m³/h
41.5 m
6 m³/h
35.5 m
7 m³/h
28 m

Key figures for this model

Motor power
1.1 kW
Flow / head range
1–7 m³/h / 28–56 m

CHLF(T)8-50

Hide curve
CHLF(T)8-503639.7543.547.255156.589.511Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

5 m³/h
51 m
6 m³/h
49.5 m
7 m³/h
47.5 m
8 m³/h
45 m
9 m³/h
42.5 m
10 m³/h
39.5 m
11 m³/h
36 m

Key figures for this model

Motor power
2.2 kW
Flow / head range
5–11 m³/h / 36–51 m

CHLF(T)15-40

Hide curve
CHLF(T)15-403337.54246.551811.51518.522Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

8 m³/h
51 m
10 m³/h
50 m
12 m³/h
48 m
14 m³/h
46 m
15 m³/h
45 m
16 m³/h
43 m
18 m³/h
40 m
20 m³/h
37 m
22 m³/h
33 m

Key figures for this model

Motor power
4 kW
Flow / head range
8–22 m³/h / 33–51 m

CHLF(T)20-40

Hide curve
CHLF(T)20-4032.537.642.847.9531014.51923.528Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

10 m³/h
53 m
12 m³/h
52 m
14 m³/h
51 m
16 m³/h
50 m
18 m³/h
48.5 m
20 m³/h
46.5 m
22 m³/h
43 m
24 m³/h
40 m
26 m³/h
36 m
28 m³/h
32.5 m

Key figures for this model

Motor power
4.4 kW
Flow / head range
10–28 m³/h / 32.5–53 m

More CHL models available

Selected models are shown. More models are available. Contact HOBER for additional models and selection support.

03 / Structure & materials

What this series is built from.

HOBER CHL Series Horizontal Multistage Solar Pump 0.37kW to 37kW
Motor
AC Induction

04 / Supply & accessories

What is supplied with this series, and what is optional.

The pump and the inverter it is matched with are supplied as one set.

Included in the supply

We confirm which inverter series fits your duty point with the quotation.

Valves, pipe connections, instrumentation and electrical accessories are not part of this set: name what you need in your enquiry and they are quoted separately.

The inverter range this series draws on

The HOBER solar pumping inverter range, tier by tier: its power classes, its electrical specification and its models.

05 / Documents

Datasheets and manuals for this series.

06 / Request a pump selection

Ask us to select the pump for your duty point.

Tell us what you need. Your name, your country and your WhatsApp number are all we need to answer — your company, your email address and your message are optional; the flow, the total head and the site, where you have them, go in your message — or say you are not sure yet and we will work them out with you.

You are asking about: CHL Solar Pump Series — CHLF(T)8-50

Your details are used only to answer this inquiry — we reply from sales@hobertek.com.

Quick Pump Selection Select Pump Select by flow & head WhatsApp Talk to HOBER