sales@hobertek.com
HOBER 6SP Series Deep Well Submersible Solar Water Pump

Solar Pump

4SP3

A four-inch family between 4SP2 and 4SP5, for small flows with head to spare.

Flow range of models shown
1.2–6 m³/h
Head range of models shown
4–441 m
Motor power of models shown
0.37–5.5 kW

Ranges are based on the positive-flow catalogue points of the models shown: the point at zero flow is the shut-off point of the curve, not a duty point. More 4SP3 models are available on inquiry. Read flow and head together on the curve for the model selected.

01 / Product & applications

Where this series is used, and the conditions it works in.

Applications

Application
Agriculture Irrigation, Deep Well Water Supply, Village Water Supply
Water source
Deep Well
Installation
Submersible
Pump type
Deep-well Submersible Centrifugal Pump
System
AC/DC Solar Pump
Power source
Solar + Grid

02 / Model selection

Selected 4SP3 Models

Selected models of this series, with their stated figures and recorded performance curves.

Selected models are shown. More models are available. Contact HOBER for additional models and selection support.

50 Hz

4SP3 models with flow and head range, curve and inquiry
Model Motor power Flow / head range Curve Inquiry
0.37 kW 1.2–6 m³/h / 4–33 m Enquire about this model
0.55 kW 1.2–6 m³/h / 7–50 m Enquire about this model
0.75 kW 1.2–6 m³/h / 9–66 m Enquire about this model
1.1 kW 1.2–6 m³/h / 11–83 m Enquire about this model
1.1 kW 1.2–6 m³/h / 13–99 m Enquire about this model
1.5 kW 1.2–6 m³/h / 16–121 m Enquire about this model
1.5 kW 1.2–6 m³/h / 18–138 m Enquire about this model
2.2 kW 1.2–6 m³/h / 23–176 m Enquire about this model
3 kW 1.2–6 m³/h / 29–215 m Enquire about this model
3 kW 1.2–6 m³/h / 32–242 m Enquire about this model
4 kW 1.2–6 m³/h / 42–320 m Enquire about this model
5.5 kW 1.2–6 m³/h / 58–441 m Enquire about this model

4SP3-06

Hide curve

50 Hz catalogue curve

4SP3-06412.320.528.83701.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
37 m
1.2 m³/h
33 m
2.4 m³/h
29 m
3 m³/h
26 m
3.6 m³/h
23 m
4.2 m³/h
19 m
4.8 m³/h
13 m
6 m³/h
4 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
0.37 kW
Flow / head range
1.2–6 m³/h / 4–33 m

4SP3-09

Hide curve

50 Hz catalogue curve

4SP3-09719.331.543.85601.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
56 m
1.2 m³/h
50 m
2.4 m³/h
43 m
3 m³/h
40 m
3.6 m³/h
35 m
4.2 m³/h
28 m
4.8 m³/h
19 m
6 m³/h
7 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
0.55 kW
Flow / head range
1.2–6 m³/h / 7–50 m

4SP3-12

Hide curve

50 Hz catalogue curve

4SP3-12925.341.557.87401.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
74 m
1.2 m³/h
66 m
2.4 m³/h
58 m
3 m³/h
53 m
3.6 m³/h
46 m
4.2 m³/h
37 m
4.8 m³/h
26 m
6 m³/h
9 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
0.75 kW
Flow / head range
1.2–6 m³/h / 9–66 m

4SP3-15

Hide curve

50 Hz catalogue curve

4SP3-151131.55272.59301.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
93 m
1.2 m³/h
83 m
2.4 m³/h
72 m
3 m³/h
66 m
3.6 m³/h
57 m
4.2 m³/h
47 m
4.8 m³/h
32 m
6 m³/h
11 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
1.1 kW
Flow / head range
1.2–6 m³/h / 11–83 m

4SP3-18

Hide curve

50 Hz catalogue curve

4SP3-181337.862.587.311201.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
112 m
1.2 m³/h
99 m
2.4 m³/h
86 m
3 m³/h
79 m
3.6 m³/h
69 m
4.2 m³/h
56 m
4.8 m³/h
39 m
6 m³/h
13 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
1.1 kW
Flow / head range
1.2–6 m³/h / 13–99 m

4SP3-22

Hide curve

50 Hz catalogue curve

4SP3-2216467610613601.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
136 m
1.2 m³/h
121 m
2.4 m³/h
106 m
3 m³/h
97 m
3.6 m³/h
84 m
4.2 m³/h
69 m
4.8 m³/h
47 m
6 m³/h
16 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
1.5 kW
Flow / head range
1.2–6 m³/h / 16–121 m

4SP3-25

Hide curve

50 Hz catalogue curve

4SP3-2518528712115501.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
155 m
1.2 m³/h
138 m
2.4 m³/h
120 m
3 m³/h
110 m
3.6 m³/h
96 m
4.2 m³/h
78 m
4.8 m³/h
54 m
6 m³/h
18 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
1.5 kW
Flow / head range
1.2–6 m³/h / 18–138 m

4SP3-32

Hide curve

50 Hz catalogue curve

4SP3-32236711115419801.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
198 m
1.2 m³/h
176 m
2.4 m³/h
154 m
3 m³/h
141 m
3.6 m³/h
123 m
4.2 m³/h
99 m
4.8 m³/h
68 m
6 m³/h
23 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
2.2 kW
Flow / head range
1.2–6 m³/h / 23–176 m

4SP3-39

Hide curve

50 Hz catalogue curve

4SP3-39298213618924201.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
242 m
1.2 m³/h
215 m
2.4 m³/h
187 m
3 m³/h
172 m
3.6 m³/h
149 m
4.2 m³/h
121 m
4.8 m³/h
83 m
6 m³/h
29 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
3 kW
Flow / head range
1.2–6 m³/h / 29–215 m

4SP3-44

Hide curve

50 Hz catalogue curve

4SP3-44329215221227201.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
272 m
1.2 m³/h
242 m
2.4 m³/h
211 m
3 m³/h
194 m
3.6 m³/h
169 m
4.2 m³/h
136 m
4.8 m³/h
94 m
6 m³/h
32 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
3 kW
Flow / head range
1.2–6 m³/h / 32–242 m

4SP3-58

Hide curve

50 Hz catalogue curve

4SP3-584212120128035901.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
359 m
1.2 m³/h
320 m
2.4 m³/h
279 m
3 m³/h
255 m
3.6 m³/h
222 m
4.2 m³/h
180 m
4.8 m³/h
124 m
6 m³/h
42 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
4 kW
Flow / head range
1.2–6 m³/h / 42–320 m

4SP3-80

Hide curve

50 Hz catalogue curve

4SP3-805816727738649501.534.56Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
495 m
1.2 m³/h
441 m
2.4 m³/h
384 m
3 m³/h
352 m
3.6 m³/h
307 m
4.2 m³/h
249 m
4.8 m³/h
171 m
6 m³/h
58 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
5.5 kW
Flow / head range
1.2–6 m³/h / 58–441 m

Complete 4SP3 range

These figures cover the whole series line and are not the figures of any one model.

Outlet size range
G1 1/4″

More 4SP3 models available

Selected models are shown. More models are available. Contact HOBER for additional models and selection support.

03 / Structure & materials

What this series is built from.

4SP3
Pump body material
AISI 304 Stainless Steel
Impeller material
AISI 304 Stainless Steel
Shaft material
AISI 304 Stainless Steel
Motor
AC Induction

04 / Supply & accessories

What is supplied with this series, and what is optional.

What the set contains, and what is quoted separately.

Included in the supply

We confirm which inverter series fits your duty point with the quotation.

Valves, pipe connections, instrumentation and electrical accessories are not part of this set: name what you need in your enquiry and they are quoted separately.

The inverter range this series draws on

The HOBER solar pumping inverter range, tier by tier: its power classes, its electrical specification and its models.

05 / Request a pump selection

Ask us to select the pump for your duty point.

Tell us what you need. Your name, your country and your WhatsApp number are all we need to answer — your company, your email address and your message are optional; the flow, the total head and the site, where you have them, go in your message — or say you are not sure yet and we will work them out with you.

You are asking about: 4SP3 — 4SP3-80

Your details are used only to answer this inquiry — we reply from sales@hobertek.com.

Quick Pump Selection Select Pump Select by flow & head WhatsApp Talk to HOBER