sales@hobertek.com
HOBER 6SP Series Deep Well Submersible Solar Water Pump

Solar Pump

6SP46

A six-inch family for medium flows, with models up to 55 kW.

Flow range of models shown
24–54 m³/h
Head range of models shown
7–437 m
Motor power of models shown
2.2–55 kW

Ranges are based on the positive-flow catalogue points of the models shown: the point at zero flow is the shut-off point of the curve, not a duty point. More 6SP46 models are available on inquiry. Read flow and head together on the curve for the model selected.

01 / Product & applications

Where this series is used, and the conditions it works in.

Applications

Application
Agriculture Irrigation, Deep Well Water Supply, Village Water Supply
Water source
Deep Well
Installation
Submersible
Pump type
Deep-well Submersible Centrifugal Pump
System
AC/DC Solar Pump
Power source
Solar + Grid

02 / Model selection

Selected 6SP46 Models

Selected models of this series, with their stated figures and recorded performance curves.

Selected models are shown. More models are available. Contact HOBER for additional models and selection support.

50 Hz

6SP46 models with flow and head range, curve and inquiry
Model Motor power Flow / head range Curve Inquiry
2.2 kW 24–54 m³/h / 7–12 m Enquire about this model
3 kW 24–54 m³/h / 14–24 m Enquire about this model
5.5 kW 24–54 m³/h / 22–35 m Enquire about this model
7.5 kW 24–54 m³/h / 29–47 m Enquire about this model
7.5 kW 24–54 m³/h / 36–59 m Enquire about this model
9.2 kW 24–54 m³/h / 43–71 m Enquire about this model
11 kW 24–54 m³/h / 50–83 m Enquire about this model
13 kW 24–54 m³/h / 58–94 m Enquire about this model
15 kW 24–54 m³/h / 65–106 m Enquire about this model
15 kW 24–54 m³/h / 72–118 m Enquire about this model
18.5 kW 24–54 m³/h / 79–130 m Enquire about this model
18.5 kW 24–54 m³/h / 86–142 m Enquire about this model
22 kW 24–54 m³/h / 94–153 m Enquire about this model
22 kW 24–54 m³/h / 101–165 m Enquire about this model
22 kW 24–54 m³/h / 108–177 m Enquire about this model
26 kW 24–54 m³/h / 115–189 m Enquire about this model
26 kW 24–54 m³/h / 122–201 m Enquire about this model
30 kW 24–54 m³/h / 130–212 m Enquire about this model
30 kW 24–54 m³/h / 137–224 m Enquire about this model
30 kW 24–54 m³/h / 144–236 m Enquire about this model
37 kW 24–54 m³/h / 151–248 m Enquire about this model
37 kW 24–54 m³/h / 158–260 m Enquire about this model
37 kW 24–54 m³/h / 166–271 m Enquire about this model
37 kW 24–54 m³/h / 173–283 m Enquire about this model
45 kW 24–54 m³/h / 187–307 m Enquire about this model
45 kW 24–54 m³/h / 202–330 m Enquire about this model
45 kW 24–54 m³/h / 216–354 m Enquire about this model
55 kW 24–54 m³/h / 238–389 m Enquire about this model
55 kW 24–54 m³/h / 252–413 m Enquire about this model
55 kW 24–54 m³/h / 266–437 m Enquire about this model

6SP46-01

Hide curve

50 Hz catalogue curve

6SP46-0178.7510.512.2514013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
14 m
24 m³/h
12 m
30 m³/h
11 m
36 m³/h
10 m
46 m³/h
9 m
48 m³/h
9 m
50 m³/h
8 m
54 m³/h
7 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
2.2 kW
Flow / head range
24–54 m³/h / 7–12 m

6SP46-02

Hide curve

50 Hz catalogue curve

6SP46-021417.2520.523.7527013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
27 m
24 m³/h
24 m
30 m³/h
22 m
36 m³/h
20 m
46 m³/h
18 m
48 m³/h
17 m
50 m³/h
16 m
54 m³/h
14 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
3 kW
Flow / head range
24–54 m³/h / 14–24 m

6SP46-03

Hide curve

50 Hz catalogue curve

6SP46-032226.7531.536.2541013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
41 m
24 m³/h
35 m
30 m³/h
33 m
36 m³/h
31 m
46 m³/h
27 m
48 m³/h
26 m
50 m³/h
24 m
54 m³/h
22 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
5.5 kW
Flow / head range
24–54 m³/h / 22–35 m

6SP46-04

Hide curve

50 Hz catalogue curve

6SP46-042935.341.547.854013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
54 m
24 m³/h
47 m
30 m³/h
44 m
36 m³/h
41 m
46 m³/h
36 m
48 m³/h
34 m
50 m³/h
32 m
54 m³/h
29 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
7.5 kW
Flow / head range
24–54 m³/h / 29–47 m

6SP46-05

Hide curve

50 Hz catalogue curve

6SP46-053644526068013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
68 m
24 m³/h
59 m
30 m³/h
55 m
36 m³/h
51 m
46 m³/h
46 m
48 m³/h
43 m
50 m³/h
40 m
54 m³/h
36 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
7.5 kW
Flow / head range
24–54 m³/h / 36–59 m

6SP46-06

Hide curve

50 Hz catalogue curve

6SP46-064352.862.572.382013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
82 m
24 m³/h
71 m
30 m³/h
66 m
36 m³/h
61 m
46 m³/h
55 m
48 m³/h
52 m
50 m³/h
48 m
54 m³/h
43 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
9.2 kW
Flow / head range
24–54 m³/h / 43–71 m

6SP46-07

Hide curve

50 Hz catalogue curve

6SP46-075061.372.583.895013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
95 m
24 m³/h
83 m
30 m³/h
77 m
36 m³/h
72 m
46 m³/h
64 m
48 m³/h
60 m
50 m³/h
56 m
54 m³/h
50 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
11 kW
Flow / head range
24–54 m³/h / 50–83 m

6SP46-08

Hide curve

50 Hz catalogue curve

6SP46-085870.883.596.3109013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
109 m
24 m³/h
94 m
30 m³/h
88 m
36 m³/h
82 m
46 m³/h
73 m
48 m³/h
69 m
50 m³/h
65 m
54 m³/h
58 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
13 kW
Flow / head range
24–54 m³/h / 58–94 m

6SP46-09

Hide curve

50 Hz catalogue curve

6SP46-096579.393.5107.8122013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
122 m
24 m³/h
106 m
30 m³/h
99 m
36 m³/h
92 m
46 m³/h
82 m
48 m³/h
77 m
50 m³/h
73 m
54 m³/h
65 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
15 kW
Flow / head range
24–54 m³/h / 65–106 m

6SP46-10

Hide curve

50 Hz catalogue curve

6SP46-107288104120136013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
136 m
24 m³/h
118 m
30 m³/h
110 m
36 m³/h
102 m
46 m³/h
91 m
48 m³/h
86 m
50 m³/h
81 m
54 m³/h
72 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
15 kW
Flow / head range
24–54 m³/h / 72–118 m

6SP46-11

Hide curve

50 Hz catalogue curve

6SP46-117996.8114.5132.3150013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
150 m
24 m³/h
130 m
30 m³/h
121 m
36 m³/h
112 m
46 m³/h
100 m
48 m³/h
95 m
50 m³/h
89 m
54 m³/h
79 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
18.5 kW
Flow / head range
24–54 m³/h / 79–130 m

6SP46-12

Hide curve

50 Hz catalogue curve

6SP46-1286105.3124.5143.8163013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
163 m
24 m³/h
142 m
30 m³/h
132 m
36 m³/h
123 m
46 m³/h
109 m
48 m³/h
103 m
50 m³/h
97 m
54 m³/h
86 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
18.5 kW
Flow / head range
24–54 m³/h / 86–142 m

6SP46-13

Hide curve

50 Hz catalogue curve

6SP46-1394114.8135.5156.3177013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
177 m
24 m³/h
153 m
30 m³/h
143 m
36 m³/h
133 m
46 m³/h
119 m
48 m³/h
112 m
50 m³/h
105 m
54 m³/h
94 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
22 kW
Flow / head range
24–54 m³/h / 94–153 m

6SP46-14

Hide curve

50 Hz catalogue curve

6SP46-14101123.3145.5167.8190013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
190 m
24 m³/h
165 m
30 m³/h
154 m
36 m³/h
143 m
46 m³/h
128 m
48 m³/h
121 m
50 m³/h
113 m
54 m³/h
101 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
22 kW
Flow / head range
24–54 m³/h / 101–165 m

6SP46-15

Hide curve

50 Hz catalogue curve

6SP46-15108132156180204013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
204 m
24 m³/h
177 m
30 m³/h
165 m
36 m³/h
153 m
46 m³/h
137 m
48 m³/h
129 m
50 m³/h
121 m
54 m³/h
108 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
22 kW
Flow / head range
24–54 m³/h / 108–177 m

6SP46-16

Hide curve

50 Hz catalogue curve

6SP46-16115141167192218013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
218 m
24 m³/h
189 m
30 m³/h
176 m
36 m³/h
163 m
46 m³/h
146 m
48 m³/h
138 m
50 m³/h
129 m
54 m³/h
115 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
26 kW
Flow / head range
24–54 m³/h / 115–189 m

6SP46-17

Hide curve

50 Hz catalogue curve

6SP46-17122149177204231013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
231 m
24 m³/h
201 m
30 m³/h
187 m
36 m³/h
174 m
46 m³/h
155 m
48 m³/h
146 m
50 m³/h
137 m
54 m³/h
122 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
26 kW
Flow / head range
24–54 m³/h / 122–201 m

6SP46-18

Hide curve

50 Hz catalogue curve

6SP46-18130159188216245013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
245 m
24 m³/h
212 m
30 m³/h
198 m
36 m³/h
184 m
46 m³/h
164 m
48 m³/h
155 m
50 m³/h
145 m
54 m³/h
130 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
30 kW
Flow / head range
24–54 m³/h / 130–212 m

6SP46-19

Hide curve

50 Hz catalogue curve

6SP46-19137167198228258013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
258 m
24 m³/h
224 m
30 m³/h
209 m
36 m³/h
194 m
46 m³/h
173 m
48 m³/h
164 m
50 m³/h
153 m
54 m³/h
137 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
30 kW
Flow / head range
24–54 m³/h / 137–224 m

6SP46-20

Hide curve

50 Hz catalogue curve

6SP46-20144176208240272013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
272 m
24 m³/h
236 m
30 m³/h
220 m
36 m³/h
204 m
46 m³/h
182 m
48 m³/h
172 m
50 m³/h
161 m
54 m³/h
144 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
30 kW
Flow / head range
24–54 m³/h / 144–236 m

6SP46-21

Hide curve

50 Hz catalogue curve

6SP46-21151185219252286013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
286 m
24 m³/h
248 m
30 m³/h
231 m
36 m³/h
215 m
46 m³/h
192 m
48 m³/h
181 m
50 m³/h
169 m
54 m³/h
151 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
37 kW
Flow / head range
24–54 m³/h / 151–248 m

6SP46-22

Hide curve

50 Hz catalogue curve

6SP46-22158193229264299013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
299 m
24 m³/h
260 m
30 m³/h
242 m
36 m³/h
225 m
46 m³/h
201 m
48 m³/h
189 m
50 m³/h
177 m
54 m³/h
158 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
37 kW
Flow / head range
24–54 m³/h / 158–260 m

6SP46-23

Hide curve

50 Hz catalogue curve

6SP46-23166203240276313013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
313 m
24 m³/h
271 m
30 m³/h
253 m
36 m³/h
235 m
46 m³/h
210 m
48 m³/h
198 m
50 m³/h
185 m
54 m³/h
166 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
37 kW
Flow / head range
24–54 m³/h / 166–271 m

6SP46-24

Hide curve

50 Hz catalogue curve

6SP46-24173211250288326013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
326 m
24 m³/h
283 m
30 m³/h
264 m
36 m³/h
245 m
46 m³/h
219 m
48 m³/h
207 m
50 m³/h
194 m
54 m³/h
173 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
37 kW
Flow / head range
24–54 m³/h / 173–283 m

6SP46-26

Hide curve

50 Hz catalogue curve

6SP46-26187229271312354013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
354 m
24 m³/h
307 m
30 m³/h
286 m
36 m³/h
266 m
46 m³/h
237 m
48 m³/h
224 m
50 m³/h
210 m
54 m³/h
187 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
45 kW
Flow / head range
24–54 m³/h / 187–307 m

6SP46-28

Hide curve

50 Hz catalogue curve

6SP46-28202247292336381013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
381 m
24 m³/h
330 m
30 m³/h
308 m
36 m³/h
286 m
46 m³/h
255 m
48 m³/h
241 m
50 m³/h
226 m
54 m³/h
202 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
45 kW
Flow / head range
24–54 m³/h / 202–330 m

6SP46-30

Hide curve

50 Hz catalogue curve

6SP46-30216264312360408013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
408 m
24 m³/h
354 m
30 m³/h
330 m
36 m³/h
307 m
46 m³/h
274 m
48 m³/h
258 m
50 m³/h
242 m
54 m³/h
216 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
45 kW
Flow / head range
24–54 m³/h / 216–354 m

6SP46-33

Hide curve

50 Hz catalogue curve

6SP46-33238291344396449013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
449 m
24 m³/h
389 m
30 m³/h
363 m
36 m³/h
337 m
46 m³/h
301 m
48 m³/h
284 m
50 m³/h
266 m
54 m³/h
238 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
55 kW
Flow / head range
24–54 m³/h / 238–389 m

6SP46-35

Hide curve

50 Hz catalogue curve

6SP46-35252308364420476013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
476 m
24 m³/h
413 m
30 m³/h
385 m
36 m³/h
358 m
46 m³/h
319 m
48 m³/h
301 m
50 m³/h
282 m
54 m³/h
252 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
55 kW
Flow / head range
24–54 m³/h / 252–413 m

6SP46-37

Hide curve

50 Hz catalogue curve

6SP46-37266325385444503013.52740.554Head (m)Flow rate (m³/h)
Catalogue curve for reference. Final pump and inverter configuration is confirmed for the required duty and installation conditions.

Catalogue reference points — flow, then head

0 m³/h
503 m
24 m³/h
437 m
30 m³/h
407 m
36 m³/h
378 m
46 m³/h
338 m
48 m³/h
318 m
50 m³/h
298 m
54 m³/h
266 m

The point at zero flow is the shut-off point of the curve, not a duty point.

Key figures for this model

Motor power
55 kW
Flow / head range
24–54 m³/h / 266–437 m

Complete 6SP46 range

These figures cover the whole series line and are not the figures of any one model.

Outlet size range
G3″

More 6SP46 models available

Selected models are shown. More models are available. Contact HOBER for additional models and selection support.

03 / Structure & materials

What this series is built from.

6SP46
Pump body material
AISI 304 Stainless Steel
Impeller material
AISI 304 Stainless Steel
Shaft material
AISI 304 Stainless Steel
Motor
AC Induction

04 / Supply & accessories

What is supplied with this series, and what is optional.

What the set contains, and what is quoted separately.

Included in the supply

We confirm which inverter series fits your duty point with the quotation.

Valves, pipe connections, instrumentation and electrical accessories are not part of this set: name what you need in your enquiry and they are quoted separately.

The inverter range this series draws on

The HOBER solar pumping inverter range, tier by tier: its power classes, its electrical specification and its models.

05 / Request a pump selection

Ask us to select the pump for your duty point.

Tell us what you need. Your name, your country and your WhatsApp number are all we need to answer — your company, your email address and your message are optional; the flow, the total head and the site, where you have them, go in your message — or say you are not sure yet and we will work them out with you.

You are asking about: 6SP46 — 6SP46-05

Your details are used only to answer this inquiry — we reply from sales@hobertek.com.

Quick Pump Selection Select Pump Select by flow & head WhatsApp Talk to HOBER