sales@hobertek.com

Inverter model

HSPH1500LB

A 1.5 kW HOBER solar pumping inverter for a single / three phase AC pump on a 220/240 V supply. For small pumps, domestic water supply and light irrigation, on a single-phase feed.

  • 1.5 kW
  • 220/240 V
  • Single / three phase
  • IP65
  • 220/240V 1-Phase
HOBER solar pumping inverter unit

0.75–2.2 kW · IP65

What this model is

HSPH1500LB is a solar pumping inverter for a 1.5 kW single / three phase AC pump: not a pump and not a panel, but the drive that stands between the two. The array’s DC comes in, the drive holds the array at its maximum power point, and what leaves it for the pump is AC at the voltage and the frequency the motor was built for. The frequency follows the array rather than a fixed supply, so the pump turns at the speed the sun can pay for at that moment, and the day’s water is pumped while the sun is up. This model states no AC input, so the array is its only source and the water pumped in a day is what the array delivers. Nothing is stored in a battery: the energy is stored as water in a tank or a reservoir.

An existing 1.5 kW AC pump does not have to be replaced to run on solar. It needs the right drive in front of it, and HSPH1500LB is that drive: the motor, the pipework and the wiring stay where they are.

For this model the datasheet states an array window of 120V minimum Vmp and 450V maximum Voc, 18A of rated input current over one string, MPPT at up to 99%, an output of 220/240 V at 50-60 Hz, an IP65 enclosure for mounting on a wall outdoors, a water level input for a well or a tank, an optional 4G/Wi-Fi module for remote monitoring and a built-in booster, which is what lets a shorter string reach that window.

What that buys is a pumping day with no meter running: the fuel bill or the grid bill that used to arrive with every hour of pumping goes, and the pump that was already paid for keeps working. The protections are built in rather than added — Solar DC input Low/Over Voltage, Solar DC input Reverse Polarity, Over Flow of Tank, Against Lightning, AC input / Output Phase Lost, Dry-Run (detecting by Sensor or Software), AC Output Short-circuit, AC Output Over Current, Over Temperature, Over Load — so a dry well, a low array or a hot afternoon costs a shutdown rather than a motor. The array is not guessed either: the array window is what the string has to sit inside, and the sizing is read from the pump’s duty point rather than from a rule of thumb.

To confirm this model against your pump, send the nameplate details — power, voltage, phase and rated current — and we check them against this model’s own figures before anything is ordered. The code to quote is HSPH1500LB.

Where it sits in the range

Single-phase 220/240 V input · 0.75–2.2 kW pump output · IP65

For small pumps, domestic water supply and light irrigation, on a single-phase feed.

Other models in this family

The datasheet for this model

Every row is a row of the source datasheet, read from this model’s own column, in the sections and the order the source prints them. A row the source does not state for this model carries an em dash rather than a figure borrowed from the model beside it.

Solar Input

Solar Input, HSPH1500LB
Parameter HSPH1500LB
Max Voc Voltage 450V
Min Vmp Voltage 120V
Recommend DC Input MPPT Voltage Built-in booster
DC Min Vmp >160V
DC Max Voc <450V
Max MPPT Efficiency 99%
Rated Input Current 18A
Number of Strings 1
Inside Booster YES

Hybrid AC Input

Hybrid AC Input, HSPH1500LB
Parameter HSPH1500LB
Voltage 220/240V 1-Phase
Rated Input Current 12.5A
Hybrid Mode N

AC Output for Pump (AC Induction Motor)

AC Output for Pump (AC Induction Motor), HSPH1500LB
Parameter HSPH1500LB
Max Adapted AC Pump Horse Power 2 HP
Max Adapted AC Pump Power 1500W
Phase Single Phase (1 phase) / 3 Phase (Compatible)
Max Output Voltage 220/240V
Max Output Frequency 50-60 Hz
Rated Output Current 13A

Other Characteristics

Other Characteristics, HSPH1500LB
Parameter HSPH1500LB
Max Efficiency 99%
Water Level Sensor (well / tank) Yes
4G/WiFi Monitor & Controller Support (Optional)
Display LCD Display (128×64)
Waterproof IP65
Noise <50dB
Cooling Method Natural Cooling
Protection Solar DC input Low/Over Voltage; Solar DC input Reverse Polarity; Over Flow of Tank; Against Lightning; AC input / Output Phase Lost; Dry-Run (detecting by Sensor or Software); AC Output Short-circuit; AC Output Over Current; Over Temperature; Over Load

Operating Environment

Operating Environment, HSPH1500LB
Parameter HSPH1500LB
Operating Environment Temperature -10 to 60°C; above 60°C need to derate load
Max Humidity 95%RH
Using Altitude <3000m; above 3000m need to derate load
Installation Restrictions Direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid, etc.

Package

Package, HSPH1500LB
Parameter HSPH1500LB
Size (L×W×H) 480×300×200mm
Weight 8KG

Inverter model

Order HSPH1500LB

Send the pump nameplate details and we confirm this model, the array it needs and the supply it expects.

Quick Pump Selection Select Pump Select by flow & head WhatsApp Talk to HOBER